TECHNICAL SPECIFICATION – DN25 WATER METER

ParameterSpecification
Nominal Diameter (DN)25 mm
Meter TypeUltrasonic
Measuring PrincipleTransit-time difference of ultrasonic signals
Accuracy ClassClass 2
Nominal Flow Rate (Q₃)4 m³/h
Overload Flow Rate (Q₄)5 m³/h
Transitional Flow Rate (Q₂)0.02 m³/h
Minimum Flow Rate (Q₁)0.01 m³/h
R Ratio (Q₃/Q₁)R400
Maximum Permissible Error (MPE)±2% (Q₂ ≤ Q ≤ Q₄), ±5% (Q₁ ≤ Q < Q₂)
Pressure ClassMAP16
Maximum Operating Pressure1.6 MPa (16 bar)
Pressure Loss ClassΔP63
Temperature ClassT50 (up to 50°C)
Maximum Permissible Temperature50°C
Nominal Pressure Loss at Q₃≤ 0.063 MPa (63 kPa)
Nominal Pipe ConnectionBSP Threaded or Sealant (as per model)
Mounting OrientationHorizontal (H)
Direction of FlowForward (arrow marked on body)
Flow Profile SensitivityU₀/D₀ = 0 / 0 (not affected by upstream/downstream disturbances)
Length of Upstream Straight Pipe10D
Length of Downstream Straight Pipe5D
Verification Scale Interval (VSI)0.1 Litre
Meter Body MaterialCPVC / UPVC
Transducer HousingEncapsulated Ultrasonic Sensor Pair
Display Unit PositionTop of Meter
Ingress ProtectionIP68
Ambient Temperature Range5°C to 80°C (as per model)
Storage Temperature Range-25°C to +70°C
Reference StandardsISO 4064-1:2014, ISO 4064-2:2014
Typical ApplicationCold potable water measurement for domestic and commercial usage